AJA Ki PRO rack Specifications Page 34

  • Download
  • Add to my manuals
  • Print
  • Page
    / 111
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 33
Ki Pro Rack v4.2 www.aja.com
34
Alarm Status
The Alarm menu displays warnings and alarms. Some alarms will automatically be shown
on the display. Others will only be seen by checking the STATUS displays (press Select up/
down to cycle through them). If everything is OK, a “SYSTEM NORMAL” message will be
seen when you cycle through the STATUS displays.
You will be alerted to an alarm condition by having all backlit keys and the display flash
to full intensity for 2 seconds. If more than one alarm state is active, the display holds
each alarm notification for 3 seconds before cycling to the next alarm. These alarm
notifications override whatever the display is currently showing for the TRANSPORT or
STATUS menus. Once there is a Ki Pro Rack alarm active (e.g. Invalid Selection) the STATUS
button light blinks for as long as the alarm is present. This alerts you so you’ll know the
reasons for the alarm condition are still active. You can then press the STATUS button to
determine what the alarm condition is.
CONFIG and MEDIA menus, once entered after an alarm notification, will cause the alarm
display to go away. Pushing any button always returns Ki Pro Rack to its pre-alarm state
however, if the alarm condition still exists after this initial button push (i.e., the reason for
the alarm), the alarm notification will reappear on the display. Note: the STATUS button
will blink if there is an active alarm condition.
Examples of ALARM displays are shown following this page. WARNING appears on the
first line and the prompted action item on the second line.
Ki Pro Rack features a variety of alarms to help you diagnose the condition of the unit,
possible configuration issues, or possible signal issues. Here is a list of warning messages
and their meanings:
"WARNING Input Format Changed" prompt appears if a recording is started and the
signal is lost or changed. If this occurs, Ki Pro Rack stops the recording in progress unless
the Loss of Video CONFIG parameter is set to continue recording.
"WARNING Record Format" may appear if there is no video input to Ki Pro Rack. No
recording will be performed in this state.
"WARNING A/V Mismatch" may appear if SDI video is selected and HDMI audio is selected
or vice versa. Embedded audio, via SDI or HDMI, must be matched to the video source.
Analog audio can be used with any video input.
SYSTEM NORMAL
WARNINIG
INVALID SELECTION
WARNING
UNRECOGNIZED MEDIA
WARNING
MEDIA IN USE
Page view 33