Chapter 2: Operation
Default Operational Settings
The V2Analog converter ships from the factory with the following configuration:
Local (DIP switch) control
Component video output
•YPbPr format
•Pedestal Off
If these settings apply to your requirements, you can simply connect the video input and
output signal cables and power up the unit.
For other applications, you can configure the unit using its DIP switch settings, or by
using MiniConfig and a PC or Mac via USB.
DIP Switch Settings
Four DIP switches are located on the bottom of the unit. The label on the bottom of the
unit identifies the functions of the switch positions. The default shipping position for
these switches is Off (down). By default, DIP switch configuration is enabled, and
MiniConfig control is disabled.
Use a pen-point or paper clip to change DIP switch positions.
Figure 3. DIP Switches.
Table 1. DIP Switch Setting Descriptions
SWITCH FUNCTION OFF (Down) ON (Up)
1 Control Selects Local (DIP), and
blocks MiniConfig control
Selects Remote (MiniConfig),
and disables DIP switches 2-4.
2 Output Selects Component Selects Composite + YC
3 Color Space Selects YPbPr Selects RGB
4 Pedestal Selects Off Selects On